Steril-Aire UVC Germicidal Systems
Discover the Solutions
Why Steril-Aire UVC Germicidal Systems?
The Steril-Aire Systems eliminate air-borne contaminants inside buildings including viruses, bacteria, molds, fungi, biofilm, allergens and volatile organic compounds (VOCs).
Why Steril-Aire?
Research conducted by Homeland Security determined Steril-Aire is 6 times more effective on average than the other available UVC systems and 150% more effective than the second best.
Steril-Aire’s UVC germicidal lamps or Emitters® work better and last longer. Independent testing proves that our UVC Emitter output is significantly higher than the competition at all temperatures. It’s all about the Energy Output: Steril-Aire UVC Germicidal emitter output provides a minimum of 1,225 μW/cm2 (microwatts) of energy as verified by Homeland Security. The Steril-Aire design software verifies 1,225 μW/cm2 of energy striking any point on the coil.
Why Steril-Aire?
Research conducted by Homeland Security determined Steril-Aire is 6 times more effective on average than the other available UVC systems and 150% more effective than the second best.
Steril-Aire’s UVC germicidal lamps or Emitters® work better and last longer. Independent testing proves that our UVC Emitter output is significantly higher than the competition at all temperatures. It’s all about the Energy Output: Steril-Aire UVC Germicidal emitter output provides a minimum of 1,225 μW/cm2 (microwatts) of energy. The Steril-Aire design software verifies 1,225 μW/cm2 of energy striking any point on the coil.
Solutions:
• Kills 99.99% of Molds, Bacteria & Viruses • Saves Energy 15% – 25% • Cleans Coils 24/7 • Eliminates Hazardous Chemical Cleaners • Improves Staff Performance • Eliminates Biofilm • Eliminates Coil Fouling/ Better Air Circulation • Improves Heat Transfer Efficiency • Cleans Contaminated Surfaces • Eliminates Odors…
Saves Energy – Eliminates Biofilm
Biofilm Thickness & Energy Costs
Fouling | Film Thickness on Fins | Increase in Energy Consumption | Additional Costs |
0.0005 | 0.006 in/150 microns | 5.3% | $13,500 |
0.0001 | 0.012 in/300 microns | 10.8% | $27,000 |
0.002 | 0.024 in/600 microns | 21.5% | $59,000 |
0.003 | 0.036 in/900 microns | 32.2% | $83,000 |
Source: California Society of Healthcare Engineering, Inc., May/June 1998 Vol. 28 No. 3
Steril-Aire & Indoor Air Quality
Absenteeism due to illness is a big concern in Hospitals, Commercial Buildings, Research Facilities, Universities, Schools and Industry. Providing the best indoor air quality (IAQ) is not an option – it’s essential. The link between indoor air pollution and the health, productivity, performance, and the comfort of patients, doctors, teachers, researchers, and staff is well documented.
Clean Coils with Steril-Aire UVC Germicidal Systems
The Cognitive Benefits of Optimal Indoor Air Quality (IAQ) in Buildings?
Steril-Aire UVC Systems can help
- 90% of building costs are occupants
- Crisis Response Improved 97%-131% with better IAQ
- Strategic Thinking Improved 183%-288%
- Information Usage Improved 172%-299%
- Reduced Absenteeism
- And More
(Source: Harvard TH Chan School of Public Health)
Food Processing
Steril-Aire’s multi-patented UVC Emitters prevent mold, bacteria, yeast and viruses from contaminating food, meat and beverage products from the preparation of raw materials through processing, curing, packaging, transportation and storage.
Steril-Aire’s UVC Emitters are ideal for surface disinfection, tumbling drums, conveyor and shaker systems, commercial refrigeration and other food processing equipment. Installed in plant HVAC and air make up systems (AMUs), UVC reduces airborne contamination before it is circulated throughout the plant.
Applications:
- Rooftop Units (RTUs)
- Indoor Air Handlers
- Fan Coil Units,
- Unit Ventilator Systems
- Packaged Terminal (PTAC)
- Heat Pumps
- Mini-Split
- Remedial In-Room Decontamination System (RIDS)
- Hand-held device designed for surface decontamination
- Ceiling HEPA PRO+ Filtration with UVC”
For More Information:
https://www.steril-aire.com
Recent News
Electronic Air Cleaning Equipment in Buildings
Open Letter to address the use of Electronic Air Cleaning Equipment in Buildings by Dr. Marwa Zaatari, Dr. Marcel Harmon Reviewed and supported by: Dr. Linsey Marr, Dr. Jose Luis Jimenez, Dr. William Bahnfleth, Dr. Shelly Miller, Dr. Jeff Siegel, Mr. Hoy Bohanon, Dr....
Changes in IAQ Caused By Corona Discharge Air Cleaner
BY TODD CRAWFORD, PATRICIA FRITZ, MEMBER ASHRAE; THOMAS WAINMAN This article was published in ASH RAE Journal, December 2018 . Copyright 2018 ASH RAE. Posted at www .ashrae.org . This article may not be copied and/or distributed electronically or in paper form without...